{"product_id":"enerji̇tem-10-kva-boxed-ip42-isolation-transformer-400-vac-input-208-vac-output-10-kva-boxed-isolation-transformer","title":"ENERJİTEM 10 Kva Boxed IP42 isolation transformer, 400 Vac Input \/ 208 Vac Output, 10 Kva Boxed isolation transformer","description":"\u003cp\u003e\u003cstrong\u003eENERJİTEM 10 Kva Boxed IP42 isolation transformer, 400 Vac Input \/ 208 Vac Output, 10 Kva Boxed isolation transformer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003e\n\u003cspan\u003eAn \u003c\/span\u003e\u003cstrong class=\"Yjhzub\"\u003eENERJİTEM 10 kVA Boxed IP42 Isolation Transformer with a 400 Vac Input \/ 208 Vac Output\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e is a \u003cmark class=\"HxTRcb\"\u003e\u003c!--qkimaf LOk2e_l\/HugV6--\u003e\u003c!--cqw1tb LOk2e_l\/HugV6--\u003e\u003cspan style=\"background-color: rgb(230, 230, 230);\"\u003eheavy-duty power conditioning and voltage conversion device\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/mark\u003e. It combines complete galvanic isolation with a \u003cstrong class=\"Yjhzub\"\u003e10 kVA power capacity\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e to step down European and international standard industrial voltage (\u003cstrong class=\"Yjhzub\"\u003e400V\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e) to standard North American low-voltage three-phase power (\u003cstrong class=\"Yjhzub\"\u003e208V\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e).\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003eTechnical Purpose of This Configuration\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eCross-Regional Equipment Compatibility:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e It allows factories operating on 400V three-phase utility grids (common in Europe, Asia, and Turkey) to safely run machinery designed for North American 208V systems.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eIsolated Local Neutral:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e By separating the primary and secondary circuits, it establishes a fresh, noise-free neutral-to-ground reference bond. This prevents ground loops from causing erratic faults in sensitive electronics.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003e66% More Power Capacity:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Compared to 6 kVA models, this 10 kVA rating provides the extra headroom needed to power heavier industrial machinery or multiple smaller tools simultaneously.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003eEngineering of the Boxed IP42 Enclosure\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eParticle Defense:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e The protective steel cabinet prevents objects larger than 1.0 mm (such as dropped screws, small tools, or flying metal shavings) from contacting live internal components.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eOverhead Liquid Protection:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e The IP42 rating shields the hot internal coils from light, vertically dripping water (up to a 15° angle), which is crucial near overhead cooling lines or facility condensation.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003ePersonnel Safety Barrier:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e It completely encloses the hazardous 400V input terminals, safeguarding maintenance crew and operators from accidental contact or arc flash risks.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003ePrimary Industry Applications\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003eThis specific 400V to 208V 10 kVA setup is widely utilized in globalized manufacturing, maritime, and testing environments:\u003cspan\u003e \u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eImported Machinery Lines:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Powering North American-made CNC machines, high-capacity 3D printers, or automated assembly cells inside factories that only have a 400V power supply.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eInternational Marine \u0026amp; Mega-Yachts:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Adapting European dockside shore power (400V) to feed a vessel's internal three-phase electrical grid, central air conditioning, and appliances designed for 208V.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eIndustrial Laboratories \u0026amp; Testing Hubs:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Supplying clean, isolated 208V power to high-draw diagnostic instruments, calibration rigs, and medical imaging gear highly sensitive to grid harmonics.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eGlobalized Data Centers:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Converting main facility 400V lines down to specialized 208V power distribution units (PDUs) used in specific IT and server rack architectures.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ENERJİTEM GLOBAL","offers":[{"title":"Default Title","offer_id":47736997413117,"sku":null,"price":1590.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8181\/5549\/files\/izoizo_dd674eca-a856-443b-84b4-5832bb34d093.png?v=1782046796","url":"https:\/\/enerjitemglobal.com\/ar\/products\/enerji%cc%87tem-10-kva-boxed-ip42-isolation-transformer-400-vac-input-208-vac-output-10-kva-boxed-isolation-transformer","provider":"ENERJİTEM GLOBAL","version":"1.0","type":"link"}