{"product_id":"enerji̇tem-15-kva-boxed-ip42-isolation-transformer-480-vac-input-208-vac-output-15-kva-boxed-isolation-transformer","title":"ENERJİTEM 15 Kva Boxed IP42 isolation transformer, 480 Vac Input \/ 208 Vac Output, 15 Kva Boxed isolation transformer","description":"\u003cp\u003e\u003cstrong\u003eENERJİTEM 15 Kva Boxed IP42 isolation transformer, 480 Vac Input \/ 208 Vac Output, 15 Kva Boxed isolation transformer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003e\n\u003cspan\u003eAn \u003c\/span\u003e\u003cstrong class=\"Yjhzub\"\u003eENERJİTEM 15 kVA Boxed IP42 Isolation Transformer with a 480 Vac Input \/ 208 Vac Output\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e is a heavy-duty power conditioning and voltage step-down device. It combines complete galvanic isolation with a \u003cstrong class=\"Yjhzub\"\u003e15 kVA power capacity\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e to safely convert high-voltage industrial power (\u003cstrong class=\"Yjhzub\"\u003e480V\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e) down to standard North American low-voltage three-phase power (\u003cstrong class=\"Yjhzub\"\u003e208V\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e).\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003eThis 15 kVA unit provides \u003cstrong class=\"Yjhzub\"\u003e50% more power than a 10 kVA model\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e, giving you the capacity to run larger, more demanding commercial equipment or entire localized sub-panels.\u003cspan\u003e \u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003eStrategic Value of the 15 kVA Capacity\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eHigher Continuous Power:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Easily supports multiple server racks, large commercial appliances, or a cluster of synchronized industrial machines simultaneously.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eMassive Inrush Management:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e The oversized magnetic core effortlessly absorbs the extreme, brief current spikes generated when heavy motors, pumps, or industrial cooling units cycle on.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eIsolated Neutral Baseline:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e By isolating the circuits, it establishes a fresh, dedicated neutral-to-ground bond on the 208V secondary side. This eliminates ground loop currents that cause erratic data and communication errors in sensitive microprocessor controls.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003eAdvantages of the Boxed IP42 Design\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eDebris Protection:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e The rugged steel enclosure blocks solid objects larger than 1.0 mm (such as stray hardware, tools, or airborne metal shavings) from touching internal high-voltage components.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eLiquid Resistance:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e The IP42 rating certifies safety against light, vertically dripping water (up to a 15° angle), shielding the transformer from overhead HVAC condensation or pipe leaks.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003ePhysical Safety Barrier:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e It completely encloses the hazardous 480V input terminals, keeping workers safe from accidental contact and minimizing arc flash risks during operation.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003eTarget Applications\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003eThis specific 480V to 208V 15 kVA configuration is widely used across facilities to run high-capacity, low-voltage infrastructure:\u003cspan\u003e \u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eHigh-Density Data Centers:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Stepping down facility-level 480V power to feed large 208V three-phase Power Distribution Units (PDUs) while completely filtering out building-wide electrical noise.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eLarge Commercial Kitchens \u0026amp; Bakeries:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Powering multiple high-draw commercial ovens, walk-in freezers, and industrial dishwashers that require a stable 208V 3-phase supply.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eMedical Laboratories \u0026amp; Imaging Suites:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Providing clean, isolated 208V power to sensitive diagnostic tools, blood analyzers, and medical imaging gear that cannot tolerate grid harmonics.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eMachine Shops \u0026amp; Fabrication Facilities:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Running clusters of 208V CNC tools, heavy-duty 3D printers, or automated packaging lines inside a standard 480V factory environment.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ENERJİTEM GLOBAL","offers":[{"title":"Default Title","offer_id":47737464455421,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8181\/5549\/files\/izoizo_dd674eca-a856-443b-84b4-5832bb34d093.png?v=1782046796","url":"https:\/\/enerjitemglobal.com\/ar\/products\/enerji%cc%87tem-15-kva-boxed-ip42-isolation-transformer-480-vac-input-208-vac-output-15-kva-boxed-isolation-transformer","provider":"ENERJİTEM GLOBAL","version":"1.0","type":"link"}