ENERJİTEM 500 Kva Boxed IP42 isolation transformer, 400 Vac Input / 400 Vac Output, 500 Kva Boxed isolation transformer
ENERJİTEM 500 Kva Boxed IP42 isolation transformer, 400 Vac Input / 400 Vac Output, 500 Kva Boxed isolation transformer
Taxes included.
Quantity
ENERJİTEM 500 Kva Boxed IP42 isolation transformer, 400 Vac Input / 400 Vac Output, 500 Kva Boxed isolation transformer
The ENERJİTEM 500 kVA Boxed IP42 Isolation Transformer (400 Vac Input / 400 Vac Output) is a premium power quality solution engineered for pure galvanic isolation without changing the voltage levels.
By maintaining a 1:1 ratio (400 Vac Input to 400 Vac Output), this 3-phase system acts as a protective shield between the raw utility grid and high-value, sensitive industrial electronics, computers, and medical equipment operating on standard European/Asian 400V distribution networks.
Technical Specifications
- Power Capacity: 500 kVA (Heavy-duty capacity for facility-wide protection, large server rooms, or multiple production lines).
- Voltage Ratio: 400 Vac Input (Primary) / 400 Vac Output (Secondary) – 3-Phase 1:1 Isolation.
- Enclosure Rating: IP42 (Boxed). Protects internal components against solid debris larger than 1 mm and angled water droplets up to 15°. Designed for reliable indoor industrial placement.
- Isolation Type: True Galvanic Isolation. Complete physical separation of the primary and secondary windings using a high-grade magnetic core.
Key Benefits
- Pure Common-Mode Noise Elimination: Blocks severe electrical line noise, high-frequency harmonics, and utility switching transients from disrupting sensitive PLC and CNC processors.
- Independent Local Grounding: Establishes a completely fresh neutral-to-ground bond on the secondary side. This eliminates ground loops and stabilizes floating neutral voltages.
- Ultimate Fault Protection: Prevents catastrophic upstream grid surges or lightning strikes from passing through to the load side, and prevents load-side short circuits from affecting the main facility grid.
Primary Applications
- Critical Data Centers: Used at the input of massive UPS systems to isolate high-frequency noise and clear ground faults from the main distribution bus.
- Precision Manufacturing: Protecting large arrays of automated machinery, robotic cells, and semiconductor equipment from voltage fluctuations and phase unbalances.
- Hospitals and Laboratories: Providing clean, stable 400V power to highly sensitive imaging devices (MRI, CT scanners) and delicate diagnostic laboratory grids.