{"product_id":"enerji̇tem-6-kva-three-phase-isolation-transformer-380-vac-input-380-vac-output","title":"ENERJİTEM 6 Kva Three Phase Isolation Transformer, 380 Vac Input \/ 380 Vac Output","description":"\u003cp\u003e\u003cstrong\u003eENERJİTEM 6 Kva Three Phase Isolation Transformer, 380 Vac Input \/ 380 Vac Output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003e\n\u003cspan\u003eA \u003c\/span\u003e\u003cstrong class=\"Yjhzub\"\u003e6 kVA Three-Phase Isolation Transformer with 380 Vac Input and 380 Vac Output\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e is an industrial-grade power conditioning device used to isolate sensitive equipment from the main electrical grid.\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003eInstead of changing the voltage level, its primary purpose is to provide \u003cstrong class=\"Yjhzub\"\u003ecomplete electrical separation\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e between the input power source and the output load to ensure safety, eliminate noise, and protect delicate electronics.\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003eBreaking Down the Technical Specifications\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003e6 kVA Power Capacity:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e This represents the maximum apparent power rating (6 Kilo-Volt-Amperes). Depending on the power factor of your load, it safely supports a continuous real power load of roughly 4.8 kW to 5.4 kW.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eThree-Phase:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Designed for industrial three-phase power systems (typically labeled as L1, L2, L3 or R, S, T). It handles balanced or unbalanced three-phase industrial loads.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eIsolation Transformer:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e The input (primary) and output (secondary) windings are completely physically separated. Power transfers purely via a \u003cstrong class=\"Yjhzub\"\u003emagnetic field\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e inside the transformer core. There is no direct electrical path between the grid and your equipment.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003e380 Vac Input \/ 380 Vac Output:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e It maintains a 1:1 voltage ratio. It accepts standard industrial 380V alternating current and outputs the exact same voltage level.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003eKey Benefits and Functions\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eShock Prevention:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Because the output side is completely isolated from the earth ground of the utility grid, accidentally touching a single live wire on the secondary side will not complete a circuit to the ground, drastically reducing the risk of electric shock.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eElectrical Noise and Harmonic Filtering:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e It acts as a barrier against high-frequency electrical noise, voltage spikes, transients, and harmonics originating from the utility grid or nearby heavy machinery.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eClean Ground\/Neutral Creation:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e It allows you to establish a brand-new, isolated neutral point on the output side, eliminating ground-loop currents and reducing the ground-to-neutral voltage down to zero.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eEquipment Protection:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Faults, short circuits, or lightning surges on either side of the transformer are heavily suppressed, preventing damage from cascading to or from the grid.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003eTypical Applications\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eMedical Equipment:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Powering sensitive diagnostic devices like MRI or CT scanners that require perfectly clean, isolated power.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eCNC and Automation:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Protecting computerized industrial machinery from grid fluctuations and voltage spikes.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eData Centers and UPS Systems:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Placed before or after Uninterruptible Power Supplies to isolate critical server racks.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eTelecommunications:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Eliminating audio\/visual hums and high-frequency interference in broadcasting and communication hubs.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e","brand":"ENERJİTEM GLOBAL","offers":[{"title":"Default Title","offer_id":47735467081981,"sku":null,"price":570.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8181\/5549\/files\/trtr3_42125c2a-422f-402d-8393-b702abac5dba.png?v=1781981093","url":"https:\/\/enerjitemglobal.com\/ru\/products\/enerji%cc%87tem-6-kva-three-phase-isolation-transformer-380-vac-input-380-vac-output","provider":"ENERJİTEM GLOBAL","version":"1.0","type":"link"}