{"product_id":"enerji̇tem-100-kva-boxed-ip42-isolation-transformer-400-vac-input-208-vac-output-100-kva-boxed-isolation-transformer","title":"ENERJİTEM 100 Kva Boxed IP42 isolation transformer, 400 Vac Input \/ 208 Vac Output, 100 Kva Boxed isolation transformer","description":"\u003cp\u003e\u003cstrong\u003eENERJİTEM 100 Kva Boxed IP42 isolation transformer, 400 Vac Input \/ 208 Vac Output, 100 Kva Boxed isolation transformer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003e\n\u003cspan\u003eAn \u003c\/span\u003e\u003cstrong class=\"Yjhzub\"\u003eENERJİTEM 100 kVA Boxed IP42 Isolation Transformer with a 400 Vac Input \/ 208 Vac Output\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e is \u003cmark class=\"HxTRcb\"\u003e\u003c!--qkimaf SN4aae_l\/HugV6--\u003e\u003c!--cqw1tb SN4aae_l\/HugV6--\u003e\u003cspan style=\"background-color: rgb(230, 230, 230);\"\u003ea high-capacity, facility-level power conditioning and voltage conversion system\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003c\/mark\u003e\u003cspan style=\"background-color: rgb(230, 230, 230);\"\u003e.\u003c\/span\u003e It combines deep galvanic isolation with a massive \u003cstrong class=\"Yjhzub\"\u003e100 kVA power capacity\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e to step down European\/International standard three-phase industrial voltage (\u003cstrong class=\"Yjhzub\"\u003e400V\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e) to standard North American low-voltage three-phase power (\u003cstrong class=\"Yjhzub\"\u003e208V\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e).\u003cspan\u003e \u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003eThis unit is a true heavy-lifter, delivering 2.5 times the capacity of a 40 kVA model, making it capable of running entire factory wings, massive server arrays, or high-draw heavy industrial plant operations.\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003eStrategic Engineering of the 100 kVA Capacity\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eMain Distribution Panel (MDP) Feeding:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e The massive 100 kVA headroom allows it to act as the primary power source for large facility sub-panels, distributing isolated 208V power to dozens of machines simultaneously.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eExceptional Inrush \u0026amp; Harmonic Management:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Designed with a massive magnetic core to handle brutal current spikes from heavy industrial motors without causing voltage drops across the system. It also dampens dangerous harmonic distortions generated by non-linear loads.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eDeep Harmonic \u0026amp; Noise Scrubbing:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e By breaking the physical connection between the 400V utility grid and the 208V load, it establishes a pristine, dedicated neutral-to-ground reference bond on the secondary side, completely eliminating ground loop currents.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003ePurpose of the Boxed IP42 Enclosure\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eHeavy Industrial Debris Shielding:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e The rugged, reinforced steel cabinet prevents any solid object larger than 1.0 mm (such as metal shavings, loose copper wires, small hand tools, or pests) from interfering with high-voltage internal coils or main busbars.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eHigh-Flow Ventilated Drip Protection:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e The IP42 architecture features specially louvred ventilation pathways. These allow massive air cooling required for a 100 kVA core while preventing vertically dripping water (up to a 15° angle) from compromising the unit.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eSubstantial Personnel Protection:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Enclosing a 100 kVA transformer is critical for arc flash containment. The heavy-duty grounded frame ensures that operators and maintenance crews are perfectly safe from hazardous high-energy exposure.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003ePrimary Industry Applications\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003eThis 400V to 208V 100 kVA configuration is deployed where massive power must cross regional standards safely and cleanly:\u003cspan\u003e \u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eLarge-Scale Imported Manufacturing Plants:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Powering extensive rows of imported North American CNC machining centers, high-capacity industrial 3D printing farms, or entire automated packaging lines inside a 400V regional factory.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eEnterprise-Grade Data Centers:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Stepping down main facility 400V infrastructure lines to safely feed multiple high-density rows of 208V Power Distribution Units (PDUs) and server racks while filtering out grid noise.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eCommercial Commercial Printing \u0026amp; Heavy Textile Mills:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Supplying isolated power to large, complex printing presses or multi-component weaving and spinning machinery built to North American voltage limits.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eMega-Yachts \u0026amp; Commercial Marine Vessels:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Transforming 400V international dockside shore power to run a vessel’s complete internal 208V three-phase grid, central HVAC chilling plants, and commercial-grade galley equipment.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ENERJİTEM GLOBAL","offers":[{"title":"Default Title","offer_id":47737745309949,"sku":null,"price":7900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8181\/5549\/files\/100-500.O1.jpg?v=1782060882","url":"https:\/\/enerjitemglobal.com\/tr\/products\/enerji%cc%87tem-100-kva-boxed-ip42-isolation-transformer-400-vac-input-208-vac-output-100-kva-boxed-isolation-transformer","provider":"ENERJİTEM GLOBAL","version":"1.0","type":"link"}