{"product_id":"enerji̇tem-100-kva-boxed-ip42-isolation-transformer-400-vac-input-400-vac-output-100-kva-boxed-isolation-transformer","title":"ENERJİTEM 100 Kva Boxed IP42 isolation transformer, 400 Vac Input \/ 400 Vac Output, 100 Kva Boxed isolation transformer","description":"\u003cp\u003e\u003cstrong\u003eENERJİTEM 100 Kva Boxed IP42 isolation transformer, 400 Vac Input \/ 400 Vac Output, 100 Kva Boxed isolation transformer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003e\n\u003cspan\u003eAn \u003c\/span\u003e\u003cstrong class=\"Yjhzub\"\u003eENERJİTEM 100 kVA Boxed IP42 Isolation Transformer with a 400 Vac Input \/ 400 Vac Output\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e is \u003cmark class=\"HxTRcb\"\u003e\u003c!--qkimaf QY4NGc_l\/HugV6--\u003e\u003c!--cqw1tb QY4NGc_l\/HugV6--\u003e\u003cspan style=\"background-color: rgb(230, 230, 230);\"\u003ea facility-level power conditioning and infrastructure protection system\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003c\/mark\u003e\u003cspan style=\"background-color: rgb(230, 230, 230);\"\u003e.\u003c\/span\u003e It provides complete galvanic isolation for 400V three-phase networks while delivering a massive \u003cstrong class=\"Yjhzub\"\u003e100 kVA power capacity\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e (2.5 times the capacity of a 40 kVA unit).\u003cspan\u003e \u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003eBecause it operates at a 1:1 voltage ratio (400V to 400V), its engineering objective is not voltage transformation, but rather \u003cstrong class=\"Yjhzub\"\u003etotal electrical separation, absolute grid purification, and high-energy safety containment\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e.\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003eStrategic Engineering of the 100 kVA Capacity\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eCentralized Grid Purification:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e The massive 100 kVA capacity allows this single unit to act as a centralized power scrubber, feeding an entire localized Main Distribution Panel (MDP), factory bay, or massive cleanroom complex.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eExceptional Inrush Absorber:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Large industrial equipment creates massive current drops upon startup. The heavy magnetic core easily absorbs these intense, brief spikes without tripping sensitive upstream breakers.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eGrounding Loop Elimination:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e It breaks physical electrical continuity and establishes a fresh, dedicated neutral-to-ground reference bond on the secondary side, completely stopping erratic ground faults from traveling between equipment and the main utility grid.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003ePurpose of the Boxed IP42 Enclosure\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eHeavy Industrial Debris Shielding:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e The rugged, reinforced steel cabinet prevents any solid object larger than 1.0 mm (such as metal filings, swarf, loose wire strands, or pests) from interfering with high-energy internal coils or main busbars.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eHigh-Flow Ventilated Drip Protection:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Features engineered, louvred cooling slots that facilitate the massive air movement required to cool a 100 kVA transformer core, while keeping out vertically dripping liquids or overhead condensation (up to a 15° tilt).\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003ePersonnel Protection \u0026amp; Arc Flash Containment:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Housing a 100 kVA transformer in a secure, grounded metal box is vital to protect facility maintenance crews and operators from accidental contact with lethal voltages and localized thermal hazards.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003ePrimary Industry Applications\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003eThis 400V to 400V 100 kVA configuration is deployed where heavy-duty equipment must be absolutely separated from dirty or unstable grid power:\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eAdvanced CNC Machinery Clusters:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Supplying clean, isolated power to extensive rows of synchronized robotic cells, heavy automotive assembly machinery, and automated packaging hubs.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eHospital Diagnostic Wings:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Supplying pristine, zero-leakage three-phase power to centralized clinical imaging centers housing heavy-draw MRI scanners, CT scanners, and delicate laboratory processing arrays.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eEnterprise-Grade Data Centers:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Protecting massive Uninterruptible Power Supply (UPS) systems and server racks from harmonic distortion and common-mode noise generated by neighboring heavy industrial facilities.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"T286Pc\"\u003e\u003cstrong class=\"Yjhzub\"\u003eCommercial Marine \u0026amp; Shipyards:\u003c!--TgQPHd||[]--\u003e\u003c\/strong\u003e Safely adapting 400V three-phase shore power to a vessel's internal 400V grid, isolating the ship's hull from dockside grounding systems to completely prevent galvanic corrosion.\u003c!--TgQPHd||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c!--TgQPHd||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ENERJİTEM GLOBAL","offers":[{"title":"Default Title","offer_id":47737787547901,"sku":null,"price":7900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8181\/5549\/files\/100-500.O1.jpg?v=1782060882","url":"https:\/\/enerjitemglobal.com\/tr\/products\/enerji%cc%87tem-100-kva-boxed-ip42-isolation-transformer-400-vac-input-400-vac-output-100-kva-boxed-isolation-transformer","provider":"ENERJİTEM GLOBAL","version":"1.0","type":"link"}